Scope of Accreditation
The facility complies with the requirements of ISO/IEC 17025:2005
3.25 Performance tests on electrical appliances and accessories For the following determinations on electric hot water heaters - Strength, pressure, torque, dimensional, temperature and hot-water delivery tests by the methods of: AS 3498 Sections 6.2, 7, Appendices A, B .12 Temperature control .41 Strength and dimensions of components .45 Endurance and life tests .99 Other tests
13.02 Metallic corrosion tests .06 Dezincification tests for brass Dezincification tests on copper alloys to AS 2345 Appendix C
13.47 Plumbing and drainage fittings .01 Baths, basins, sinks, showers for the following determinations - Flow rate, spread angle, temperature drop, tensile strength, watertightness, temperature, thermal shock, connections by the methods of - AS 3662 Sections 5.1, 5.2, 5.3, 5.5, 5.6, 5.7, Appendices B, C, D, E, F, G
.02 Sanitary ware for the following determinations - Back flow, capacity, contaminant, discharge, distortion, endurance, fixing, flow rate, flush performance, leakage, load, splash, strength, thrust, water seal, wetting by the methods of - AS 1172.1 Sections 3.1, 3.2, 3.3, 3.4, 3.5, 3.6, 3.7, 3.8, Appendices A, B, C, D, E, F, G, H AS 1172.2 Sections 3.5, 4.5, 5.4, 6.4, Appendices A, B, C, D, E, F, G, H, I, L, M AS/NZS 3982 Section 1.6 Appendices A, B, C, D
.03 Taps and valves for the following determinations - Dimensional, endurance, discharge, flow rate, leakage, pressure, strength, temperature, torque, watertightness by the methods of - AS 1357.2 Sections 3.2, 4.6, 4.7, 4.8, 4.9, 5.3, 5.4, 5.5, 5.6, 5.7, 6.4, 6.5, 6.6, 7.2, 7.4, 7.5, 8.4, 8.5, Appendices E, F, G, H, I, K, L, M, N, O, P AS 1432 Section 5.4.2, Appendix E AS 1628 Sections 4.2, 4.3, 4.4, 4.5, 4.6, Appendices B, C, D AS 2419.2 Sections 4.2, 4.3, Appendices D, E AS/NZS 2845.1 Sections 3.7, 4.5, 5.5, 6.5, 7.4, 8.5, 9.5, 10.5, 11.4, 12.5, 13.4, 14.5, 15.5, 16.5, 17.5, 18.4, Appendices A, C, D, E, F, G, H, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Y, Z, AA, BB, CC, DD, EE, FF, GG, HH, II, JJ, KK, LL, MM, NN, OO, PP, QQ, RR, SS, TT AS 3952 Section 5.1 AS/NZS 2638.1 Sections 5.1.2, 5.1.3, 5.1.4, 5.1.5, 5.1.6, 5.1.7, 5.1.8, 5.1.9, 5.1.10, 5.1.11, 5.1.12 AS/NZS 2638.2 Sections 5.1.2, 5.1.3, 5.1.4, 5.1.5, 5.1.8, 5.1.9, 5.1.10, 5.1.11, 5.1.12 AS/NZS 3718 Sections 4.3, 4.4, 4.5, 4.6, 4.8, 4.9, 4.10, 4.11, 4.12, 4.13, 4.14, 4.15, Appendices D, E, F, G, H, I, J, K, L, M, N, O, Q, R NZS 4522 Sections 7.2.1, 7.2.2, 7.2.3, 7.2.4, 7.2.5, 7.2.6, 7.2.7, 7.2.8, 7.3, 7.4 ISO 5208 Table 1.1
.04 Pipes, controllers, connections and other fittings for the following determinations - Colour, dimensions, endurance, flow characteristics, impact, load test, pressure, pressure cycling, strength, thermal cycling, torque by the methods of - AS 2888.1, .2, .3, .4, .5, .6, .7, .8, .9, .10, .11 AS 3688 Sections 4.2, 4.3, 4.4, 4.5, 4.6, 4.7, 4.8, 4.9, 4.10, Appendices D, E, F, G, H, I, J, K, L AS/NZS 3707 (referenced by AS 3688 Section 4.4 and AS 2642.3 Section 12.2.6) AS 4176:1994 Sections 2.1.1, 2.1.2, 2.1.4, 2.1.5, 2.2.1, 2.2.2, 2.3.1, 2.3.2, 3.1.1, 3.1.4, 3.1.5, 3.1.6, 3.2.1, 3.2.2, 3.2.3, 3.2.4, 3.2.5, 3.3.1, 3.3.2, 3.3.3, 3.3.4, 3.3.5, D, E, G AS 4176.8 Section 7.3, Annexes G, H, I, K AS/NZS 1260 Sections 2.3, 3.2.6, 3.3.1, 3.3.2, 3.3.3, 3.3.4, 3.3.5, 3.4.2, 3.4.3, 3.4.4, AS/NZS 1462.1, .3, .4, .5, .6, .8, .9, .11, .13, .16, .17, .20, .24 AS/NZS 1477 Sections 2.4, 3.3.1, 3.3.2, 3.3.3, 3.3.4, 3.3.6, 3.4.1, 3.4.2, 3.4.3, 3.4.4, 3.5.1, 3.5.2 AS/NZS 1571 Section 12 AS/NZS 2492 Sections 3.9, 3.10, Tables 3.3, 3.4 AS/NZS 2642.3 Sections 12.2, 12.3, Appendices C, D, E, F and torque tests for compliance with Section 11 AS/NZS 3499 Sections 8.2, 8.3, 8.4, 8.6, 8.7, 8.8, 8.9, Appendices C, D AS/NZS 4129 Sections 1.13, 2.4.2, 2.4.3, 2.4.4, 2.4.5, 3.5 (Tables 3.2 and 3.4), 4.4.2, 4.4.3, 4.4.4, 4.4.5, 4.4.6, 6.8 (Table 6.3) Appendices E, F AS/NZS 4130 Sections 10.1, 10.2, 10.4 AS/NZS 4327 Sections 4.3.2, 4.3.3, Appendices E, F EN 12117 (referenced by AS/NZS 4129 Table 3.2) ISO 1167 (referenced by AS/NZS 2492 Table 3.3 and AS 4129) ISO 3126 (referenced by AS/NZS 4129 clause 3.4.1) ISO 3459 (referenced by AS/NZS 4129 clauses 2.4.3 and 4.4.2) ISO 3501 (referenced by AS/NZS 4129 clause 2.4.5) ISO 3503 referenced by AS/NZS 4129 clauses 2.4.4 and 4.4.3 ISO 6259-1 (referenced by AS/NZS 2492 Table 3.3) ISO 6259-2 (referenced by AS/NZS 2492 Table 3.3) ISO 10147 (referenced by AS/NZS 2492 Table 3.4) ISO 13477 (referenced by AS/NZS 2492 Table 3.3) ISO 13479 (referenced by AS/NZS 2492 Table 3.3) ISO 13953 (referenced by AS/NZS 4129 Table 6.3) ISO 13954 (referenced by AS/NZS 4129 Table 3.2) ISO 13955 (referenced by AS/NZS 4129 Table 3.2) ISO 13957 (referenced by AS/NZS 4129 Table 3.2) ISO 18553 (referenced by AS/NZS 2492 Table 3.4) ISO/TR 10837 (referenced by AS/NZS 2492 Table 3.4) ISO 14531-1 Annex C (referenced by AS/NZS 2492 Table 3.4) ISO 2505 (referenced by AS/NZS 2492 Table 3.4)
13.99 Other materials and products Hydrostatic, endurance and burst pressure tests on drinking water treatment units and components to AS/NZS 3497 Sections 5.2, 5.3, 5.4 and 5.6
|